Abstract
Disinfectants are widely used in water treatment to control pathogens, the resulting disinfection by-products (DBPs) have been found or suspected to pose health risks. There are limited studies on rapid detection methods for the measurement of DBPs. An ion chromatography method was established for the simultaneous determination of five trace-level DBPs in drinking water, enabling their routine and rapid monitoring in the study. Interferences from major inorganic anions in drinking water were eliminated by optimizing the mobile phase flow rate, gradient program, and column temperature. With an injection volume of 500 µL, the limits of detection (LODs) ranged from 0.55 µg/L to 1.40 µg/L, while the relative standard deviations (RSDs) for peak area and retention time were 1.36%-3.02% and 0.11% ‑0.36%, respectively. The accuracy and precision were evaluated by adding three concentration levels to three different types of water. The recovery rates ranged from 92.7% to 108.0%, and the RSD rates ranged from 0.06% to 1.54%. Furthermore, the proposed method was applied to the quantification of five DBPs in 74 drinking water samples collected from both urban and rural areas, and its applicability was systematically evaluated. The results demonstrate that the method enables the simultaneous, rapid, and accurate quantification of these trace DBPs, thereby serving as a sensitive and reliable analytical tool while concurrently providing preliminary data essential for public health surveillance.
Acknowledgements
We appreciate the insightful comments from the anonymous reviewers.
Funding
This research was financially supported by the Yichang Municipal Government (Rural Drinking Water Project, Urban and Rural Drinking Water Project).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Supplementary Material 1 (download DOCX )
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Reprints and permissions
About this article
Cite this article
Xie, Y., Li, B., Wan, Z. et al. Trace determination of five disinfection by-products in drinking water by ion chromatography.
Sci Rep (2026). https://doi.org/10.1038/s41598-026-71389-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-026-71389-2
Keywords
- Drinking water
- Disinfection by-products
- Haloacetic acids
- Inorganic oxyhalide
- Ion chromatography
Source: Resources - nature.com